Project name
Towrope and Winch
Location
Queensland
Country
Australia
Market area
Marine

 

Requirement
The 750mm diameter AFT towropes were used only once every 6-12 months. Previous products used had failed to give adequate corrosion protection to the inner core, leading to concerns about the integrity of the rope. The client needed to be sure that the rope was protected internally and externally, and that the winch was also protected, so that the equipment would function when needed.
Surface Preparation
The items were jetted with fresh water and allowed to dry.
Coatings
Corroless CCI 350 Grease.
Corroless CCI 400 Wax.
The towrope was laid out on the dock and CCI 350 was applied as it was rewound onto the drum.
The whole drum and winch assembly was then sprayed with CCI 400